Gerald F. Greil, Andrew J. Powell, Hans P. Gildein, Tal Geva
Children’s Hospital, Boston.
United States
Journal of the American College of Cardiology
J Am Coll Cardiol 2002; 39: 335-341
DOI: 10.1016/s0735-1097(01)01730-2
Abstract
Objective: The goal of this study was to evaluate the diagnostic value of gadolinium (Gd)-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) in patients with congenital and acquired anomalies of the pulmonary and systemic veins.
Background: Gadolinium-enhanced 3D MRA is a fast magnetic resonance imaging technique that has shown great promise in the evaluation of large and medium-sized arteries. However, its application to venous anomalies has not been studied in detail.
Methods: The study retrospectively analyzed all patients who underwent Gd-enhanced 3D MRA examination from January 1998 through January 2001, were diagnosed with anomalies of the pulmonary or systemic veins and had additional diagnostic data available for comparison with the MRA findings.
Results: Sixty-one patients (age 1 day to 60 years) were included. Image acquisition was completed in 29 +/- 6.9 s. Pulmonary venous anomalies were found in 37 patients, systemic venous anomalies in 17 patients and both pulmonary and systemic venous anomalies in 7 patients. Compared with available diagnostic information by other modalities, all known or suspected venous anomalies were imaged by 3D MRA. In three patients, catheterization did not detect anomalies of the pulmonary veins that were subsequently diagnosed by MRA. The 3D MRA diagnoses were followed by 10 interventional catheterization procedures and 15 operations. In 74% of patients, 3D MRA either diagnosed previously unsuspected venous anomalies (28%) or added new clinically important information (46%). The mechanism of pulmonary vein compression in eight patients was determined by MRA but not by other imaging modalities. Using a five-level grading system for MRA image quality (1 = nondiagnostic; 5 = excellent), the average grade was 4.6 +/- 0.6, with a 0.28 +/- 0.6 mean grade difference between two independent observers.
Conclusions: Gadolinium-enhanced 3D MRA is capable of rapidly and accurately diagnosing a wide spectrum of pulmonary and systemic venous anomalies and is a useful noninvasive alternative to diagnostic catheterization.
Category
Stenosis or Obstruction of Normal Pulmonary Venous Connections
Stenosis or Obstruction of Pulmonary Veins Following Surgical Repair of Anomalous Pulmonary Venous Connections
Diagnostic Testing. Noninvasive
Year of Publication: 2002
Age Focus: Pediatric
Article Type: Retrospective Observational Cohort Studies (>10 patients)
Article Access: Free PDF File or Full Text Article Available Through PubMed or DOI: Yes